qsk60 generator

QSK60 for Commercial Industrial

Frequency (Hz) 50, 60
Certification TA Luft 4g, EPA Tier 4F, EPA Tier 2, TA Luft 2g, EPA Tier 4i
Fuel Type Diesel
Rated for kW kVa
Standby 1408-2750 1760-3438
Demand Response 1800-2500 2250-3125
Continuous 2100 2625

Overview:

  • Cummins® heavy-duty engine - Rugged 4-cycle, industrial diesel delivers reliable power, low emissions and fast response to load changes.
  • Alternator - Several alternator sizes offer selectable motor starting capability with low reactance 2/3 pitch windings, low waveform distortion with non-linear loads and fault clearing short-circuit capability.
  • Permanent magnet generator (PMG) - Offers enhanced motor starting and fault clearing short-circuit capability.
  • Control system - The PowerCommand® electronic control is standard equipment and provides total genset system integration including automatic remote starting/stopping, precise frequency and voltage regulation, alarm and status message display, AmpSentry™ protection, output metering, autoshutdown at fault detection and NFPA 110 Level 1 compliance.
  • Cooling system - Standard integral set-mounted radiator system, designed and tested for rated ambient temperatures, simplifies facility design requirements for rejected heat.
  • NFPA - The genset accepts full rated load in a single step in accordance with NFPA 110 for Level 1 systems.
  • Warranty
Generator Model Hz Continuous kVA / kW Demand Response kVA / kW Prime kVA / kW Standby kVA / kW Fuel Type Certification Spec Sheet
C1760 D5e 50 1600 / 1280 1600 / 1280 1760 / 1408 Diesel 2g TA Luft SS17-CPGK
DQKAH 50 1400 / 1120 1825 / 1460 1825 / 1460 2000 / 1600 Diesel 2g TA Luft S-1645
C2000 D5e 50 1825 / 1460 1825 / 1460 2000 / 1600 Diesel 2g TA Luft SS17-CPGK
C2000 D5 50 1875 / 1500 2063 / 1650 Diesel SS17-CPGK
C2000 D5 50 1875 / 1500 1875 / 1500 2063 / 1650 Diesel SS17-CPGK
DQKAK 60 1813 / 1450 2000 / 1600 2000 / 1600 2188 / 1750 Diesel EPA Tier 4i S-1676
DQKAD 60 1813 / 1450 2000 / 1600 2000 / 1600 2188 / 1750 Diesel EPA Tier 2 S-1627
DQKAG 50 1400 / 1120 2000 / 1600 2000 / 1600 2250 / 1800 Diesel 2g TA Luft S-1645
C2250 D5 50 2000 / 1600 2250 / 1800 Diesel SS17-CPGK
C2250 D5 50 2000 / 1600 2000 / 1600 2250 / 1800 Diesel SS17-CPGK
DQKAE 60 2000 / 1600 2281 / 1825 2281 / 1825 2500 / 2000 Diesel EPA Tier 2 S-1627
DQKAJ 50 1650 / 1320 2250 / 1800 2000 / 1600 2500 / 2000 Diesel 2g TA Luft S-1645
DQKAL 60 2000 / 1600 2281 / 1825 2281 / 1825 2500 / 2000 Diesel EPA Tier 4i S-1676
C2000 D6 60 2281 / 1825 2281 / 1825 2500 / 2000 Diesel SS17-CPGK
C2500 D5A 50 2250 / 1800 2500 / 2000 Diesel SS17-CPGK
C2500 D5A 50 2250 / 1800 2250 / 1800 2500 / 2000 Diesel 4g TA Luft SS17-CPGK
DQKAF 60 2500 / 2000 2500 / 2000 2281 / 1825 2813 / 2250 Diesel EPA Tier 2 S-1627
DQKAM 60 2500 / 2000 2813 / 2250 Diesel EPA Tier 4F S-1676
C2250 D6A 60 2500 / 2000 2813 / 2250 Diesel SS17-CPGK
DQKAN 60 2813 / 2250 3125 / 2500 Diesel EPA Tier 2 NAS-5918-EN
DQLH 60 2625 / 2100 3125 / 2500 3438 / 2750 Diesel EPA Tier 4F S-1677


To access our complete brochure library, click here.