QSK60

QSK60 for High Horsepower Commercial Industrial

Frequency (Hz) 50, 60
Certification TA Luft 4g, EPA Tier 4F, EPA Tier 2, TA Luft 2g, EPA Tier 4i
Fuel Type Diesel
Rated for kW kVa
Standby 1408-2500 1760-3125

Applications

High Horsepower Commercial Industrial Commercial Industrial Data Centers

Overview:

This Cummins® commercial generator set is a fully integrated power generation system, providing optimum performance, reliability, and versatility for stationary standby, prime power, and continuous duty applications.

  • Design: 4 cycle, V-block, turbo charged low temperature and after-cooled
  • Bore: 158.8 mm
  • Stroke: 190 mm (7.48 in.)
  • Displacement: 60.2 L (3673 in.3)
  • Cylinder block: Cast iron, V16
  • Battery capacity: 220 amps at ambient temperature 0°F to 32°F (-18°C to 0°C)
  • Battery charging alternator: 40 amps
  • Starting voltage: 24 volts, negative ground
  • Fuel system: Direct injection
  • Ignition system: Individual coil on plug
  • Air cleaner type: Dry replaceable element
  • Lube oil filter type(s): DC Four spin-on, combination full flow and bypass filters
  • Standard cooling system: 104°F (40°C) ambient radiator
Generator Model Hz Continuous kVA / kW Data Center Continuous kVA / kW Demand Response kVA / kW Prime kVA / kW Standby kVA / kW Fuel Type Certification Spec Sheet
C1760 D5e 50 1600 / 1280 1600 / 1280 1760 / 1408 Diesel 2g TA Luft SS17-CPGK
C2000 D5e 50 1825 / 1460 1825 / 1460 2000 / 1600 Diesel 2g TA Luft SS17-CPGK
DQKAH 50 1400 / 1120 1825 1460 1825 / 1460 2000 / 1600 Diesel 2g TA Luft S-1645
C2000D5 (Unhoused) 50 1875 / 1500 1875 / 1500 2063 / 1650 Diesel SS17-CPGK
C2000D5 (Unhoused, ISO Container) 50 1875 / 1500 2063 / 1650 Diesel EA_T_CC_3_EN
C2250D5 (Unhoused, ISO Container) 50 2000 / 1600 2250 / 1800 Diesel EA_T_CC_3_EN
C2250D5 (Unhoused) 50 2000 / 1600 2000 / 1600 2250 / 1800 Diesel SS17-CPGK
DQKAG 50 1600 / 1280 2000 / 1600 2000 / 1600 2250 / 1800 Diesel 2g TA Luft S-1645
C2500D5A (Unhoused) 50 2250 / 1800 2250 / 1800 2500 / 2000 Diesel SS17-CPGK
DQKAJ 50 2250 / 1800 2000 / 1600 2500 / 2000 Diesel 2g TA Luft S-1645
C2500D5A (Unhoused, ISO Container) 50 2250 / 1800 2501 / 2000 Diesel 4g TA Luft EA_T_CC_3_EN
C2750D5B 50 2500 / 200 2500 / 2000 2750 / 2200 Diesel NAS-6089-EN
DQKAD 60 1821 / 1450 2000 / 1600 2000 / 1600 2188 / 1750 Diesel EPA Tier 2 S-1627
DQKAA 60 2000 / 1600 2188 / 1750 Diesel EPA Tier 4i S-1514
DQKAB 60 2281 / 1825 2281 / 1825 Diesel EPA Tier 4F S-1514
DQKAE 60 2000 / 1600 2281 / 1825 2281 / 1852 2500 / 2000 Diesel EPA Tier 2 S-1627
C2000D6 60 2281 / 1825 2281 / 1825 2500 / 2000 Diesel SS17-CPGK
C2250D6A 60 2500 / 2000 2813 / 2250 Diesel SS17-CPGK
DQKAF 60 2500 / 2000 2281 / 1852 2812 / 2250 Diesel EPA Tier 2 S-1627
DQKAM 60 2500 / 2000 2281 / 1825 2813 / 2250 Diesel EPA Tier 4F S-1676
DQKAN 60 2183 / 2250 3125 / 2500 Diesel EPA Tier 2 NAS-5918-EN

Cummins heavy-duty engine - Rugged 4- cycle, industrial diesel delivers reliable power, low emissions and fast response to load changes.

Alternator - Several alternator sizes offer selectable motor starting capability with low reactance 2/3 pitch windings, low waveform distortion with non-linear loads and fault clearing short-circuit capability.

Permanent Magnet Generator (PMG) - Offers enhanced motor starting and fault clearing short circuit capability.

Control system - The PowerCommand® digital control is standard equipment and provides total genset system integration including automatic remote starting/stopping,precise frequency and voltage regulation, alarm and status message display, AmpSentryTM protective relay, output metering and auto-shutdown at fault detection and NFPA 110 Level 1 compliance.

Cooling system - Standard and enhanced integral set-mounted radiator systems, designed and tested for rated ambient temperatures, simplifies facility design requirements for rejected heat.

NFPA - The genset accepts full rated load in a single step in accordance with NFPA 110 for Level 1 systems. 

Uptime Compliant - Meets the requirement of a Tier III and IV data center site by being rated to run for unlimited hours of operation when loaded to 'N' demand for the engine generator set.

Warranty and service - Backed by a comprehensive warranty and worldwide distributor network. 

Data Center Continuous (DCC) - Applicable for supplying power continuously to a constant or varying electrical load for unlimited hours in a data center application. 



To access our complete brochure library, click here.
Case Study Actions

Cummins helps expand a major water treatment plant

View


To view all case studies, click here.
Redirecting to
cummins.com

The information you are looking for is on
cummins.com

We are launching that site for you now.

Thank you.